Product Description

High Quaity Integrated Medical Central  Gas Supply System

ETR Medical Central Gas Supply System Description
The medical Central Gas Supply system plays a significant role in modern hospitals. The appropriate design and setup of medical gas equipment are essential for the hospitals to ensure medical quality, as well as to save the lives and ease the pain of patients in a timely manner. The medical center gas supply system is mainly composed of the gas station, Bed Head Unit, gas terminal, electrical system, medical calling system, medical pipelines and auxiliary equipment system.

No.
Model
Capacity
(NM3/hr)

Compressed Air Source
(M3/min)

Air Compressor
(KW)

Buffer Tank
1
ETO-01
0.8-1.2
0.16-0.24
2.2
50L
2
ETO-02
1.5-2
0.24-0.32
3
100L


2.1-2.5
0.35-0.45
4
100L
3
ETO-03
2.5-3
0.63-0.75
5.5
300L
4
ETO-05
3.5-5
0.9-1.2
7.5
300L
5
ETO-10
5.5-7
1.38-1.75
11
500L


8.0-10
2.0-2.5
15
500L
6
ETO-15
11-12
2.8-3.0
18.5
1000L


13-15
3.25-3.75
22
1000L
7
ETO-20
16-17
4.0-4.24
26
1500L


18-20
4.4-4.8
30
1500L
8
ETO-30
21-25
5.25-6.0
37
2000L


26-30
6.5-7.5
45
2000L
9
ETO-40
32-36
8.0-9.0
55
2500L


38-42
9.5-10.5
55+
2500L
10
ETO-50
45-50
11-12.5
75
3000L

ETR Central Gas Supply System Advantage

  • Highly efficient molecular sieves, making oxygen generation more efficient
  • Unique startup concentration maintenance function
  • Imported muffler, achieving an operating noise of less than 85dB(A)
  • LCD touch screen interface, making setting of operating parameters more convenient
  • Integrated pipeline process, providing excellent air tightness
  • Intelligent control, enabling remote data transmission.


SPEC of ETR Oxygen Generation System


ETO-15 Oxygen Generator
Item Specification Remark
Oxygen Capacity 1-50Nm3/h Normal/Standard Condition
Oxygen Purity 93%±3%
Oxygen Delivery Pressure 0-4bar  Adjustable
Power Consumption 0.1-0.2kW 220V, 50Hz @1Phase
Dimensions (mm) / Including buffer tanks. Dimensions are approximate.
Weight (kg) / Weight is approximate.
Noise Level ≤85dB(A) 1 meter away
Compressed Air Specifications
Air Flow Rate Required As Demand Capacity Of The Clean & Dry Air after Pretreatment
Pressure ≥7bar Gauge
Oil residual Content 0.008PPm
Particles Size 0.01m
Pressure Dew Point + 3ºC
Air Temperature 5-45 Deg. C
Design Working Conditions
Relative humidity 20%-100%
Dust Content In The Air ≤20mg/m3
H2S,SO2 Content In The Air ≤5ppm 
CO2 Content In The Air ≤250ppm
CnHm Content In The Air ≤20ppm
Acidic Gases  Less Than Stimulus
Content And Without Erosive Gases 
Self-governed Room For Air Separation Plant And Far From Acidic Environment is Strongly Recommended

5. Quality Control Process

ETR Enigineering & Technology,clients can be sure of the quality of ETR solution. ETR uses only the best suppliers and components. And  all oxygen generators are tested & commissioned by professional Experts to make sure everything is qualified before they leave the factory.


COMPANY INTRODUCTION

Eter founded in 2003 and listed on the NEEQ (National Equities Exchange and Quotations) with the stock code of 839074 in 2016.

Eter is the mainly Integrated Solution provider for Medical Engineering such as medical oxygen generation solution/vacuum negative pressure suction solution/ medical oxygen cylinders filling solution/Hospital Bed Head Unit solution/Nurse Call System etc.

Eter is the one of most qualified producers in China market. In addition to the International market, the ETR products have been exported to Southeast Asia, Africa, the Middle East and other overseas markets.
Eter is UN qualified  product supplier.


AFTER SALES SUPPORT
Warranty
The Guarantee/Warranty Period shall be a period of twelve months after on-site startup & commissioning or eighteen months after shipment, whichever occurs first. If any trouble or defect, originating with the design, material, workmanship or operating characteristics of any Goods, arises at any time during GUARANTEE/WARRANTY period, ETR shall, at his own expense and as promptly as possible, make such alterations, repairs and replacements.
On-Site Support
ETR can do paid services of on-site startup, commissioning, installation supervision, training, by providing purchaser with the services of qualified English-speaking
engineer at site. ETR shall obtain all permits and licenses required to perform the services under this Agreement.

Contact us_02


Product Categories : Medical Engineering System > Central Gas Supply System

Product Images

  • Integrated Medical Central  Gas Supply System
  • Integrated Medical Central  Gas Supply System
  • Integrated Medical Central  Gas Supply System
  • Integrated Medical Central  Gas Supply System
  • Integrated Medical Central  Gas Supply System
Email to this supplier
  • Mr. Terry Zhou
  • Your message must be between 20-8000 characters

Related Productslist

Home

Phone

Skype

Inquiry